General review of titanium toxicity

15 Apr.,2024

 

This article is distributed under the terms of the Creative Commons Attribution 4.0 International License ( http://creativecommons.org/licenses/by/4.0/ ), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

Clinicians should pay attention to the use of titanium dental implants, and need to be aware of the problems that may arise from the use of titanium implants and should be able to diagnose them, in spite of very rare occurrence.

Clinicians should pay attention to the use of titanium dental implants and need to be aware of the problems that may arise from the use of titanium implants and should be able to diagnose them, in spite of very rare occurrence. Within the limitation of this study, it was suggested that we should be aware the rare problems of titanium toxicity.

Recent studies with regard to titanium toxicity have been increasing and have now expanded to the medical field in addition to the fields of environmental research and basic science. Problems that may arise in titanium-based dental implants include the generation of titanium and titanium alloy particles and ions deposited into surrounding tissues due to the corrosion and wear of implants, resulting in bone loss due to inflammatory reactions, which may lead to osseointegration failure of the dental implant. These titanium ions and particles are systemically deposited and can lead to toxic reactions in other tissues such as yellow nail syndrome. Additionally, implant failure and allergic reactions can occur due to hypersensitivity reactions. Zirconia implants can be considered as an alternative; however, limitations still exist due to a lack of long-term clinical data.

We used online searching tools including MEDLINE (PubMed), Embase, Cochrane Library, and Google Scholar by combining keywords such as “titanium implant toxicity,” “titanium implant corrosion,” “titanium implant allergy,” and “yellow nail syndrome.” Recently updated data has been collected and compiled into one of four categories: “the toxicity of titanium,” “the toxicity of titanium alloys,” “the toxicity of titanium implants,” and “diseases related to titanium.”

Titanium is a commonly used inert bio-implant material within the medical and dental fields. Although the use of titanium is thought to be safe with a high success rate, in some cases, there are rare reports of problems caused by titanium. In most of these problematic reports, only individual reports are dominant and comprehensive reporting has not been performed. This comprehensive article has been prepared to review the toxicity of titanium materials within the medical and dental fields.

The purpose of this article is to provide a general overview of the stability and risk associated with titanium materials and to suggest alternative solutions. We examined the toxicity of titanium through a division into four categories: the toxicity of titanium, the toxicity of titanium alloys, the toxicity of titanium implants, and diseases related to titanium.

Titanium is also used commonly in industrial applications such as coatings for pharmaceuticals, processing materials for gum and confections, food additives, and paints. In the medical field, titanium and titanium alloys have been used to fabricate various of implantation and fixation systems. With the widespread use of titanium, there are concerns regarding the adverse effects of titanium accumulation and its effects on the human body [ 21 , 22 ]. Therefore, stability and potential hazards of titanium should also be evaluated and discussed.

Titanium is one of the most widely used materials for dental implants due to its mechanical strength, biocompatibility, and a long history of use [ 1 , 2 ]. Current titanium dental implants possess a high success rate; however, failures are still being reported [ 3 – 5 ]. Cause of these implant failures can be poor oral hygiene, uncontrolled deposition of plaque, and calculus around the implant which cause peri-implantitis or occlusal problems. In the light of new investigations in biological and mechanical aspects, the allergy response to dental implant materials and toxicity of the particle released from implant system are reported to have a role in implant failure [ 6 , 7 ]. There are also a variety studies on titanium and its alloys as well as implant surface treatment materials to determine their toxicity behavior and its mechanism [ 8 , 9 ]. Typical examples include bone loss due to inflammation reactions due to implant corrosion [ 10 – 12 ], hypersensitivity to titanium and allergic reactions [ 13 – 16 ], and yellow nail syndrome [ 17 – 20 ].

In order to investigate the relevance of the main topic with recent studies, we collected the data from 1991 to November 2018 and keywords were also limited to “titanium toxicity human,” “titanium alloy toxicity human,” “titanium implant toxicity,” “titanium corrosion,” and “yellow nail syndrome titanium”; thus, 1820 articles were found. Additionally, another 464 articles that were found from the “titanium implant corrosion” keyword and another 84 articles that were found from the “titanium implant allergy” keyword were further identified and included in the “toxicity of titanium implant” category.

Results

Extensive data was searched as mentioned in the research methods. According to the data analysis, the number of papers from 2011 to 2015 was the highest at 730; the research shows a trend of rapid increase in recent years with the large number of papers from 2016 to 2018. In the author’s field of specialization, 995 fields of basic science were the most studied; fields within environmental science and basic science were extended to the medical field (Table  ). The toxicity of titanium implants revealed 734 results, including titanium corrosion and titanium hypersensitivity, 1229 articles for titanium toxicity, 149 toxicities for titanium alloy, and 256 articles for yellow nail syndrome, a titanium-related disease (Table  ).

Table 1

1991–19951996–20002001–20052006–20102011–20152016–2018Titanium toxicity305881216432412Titanium alloy toxicity121730184032Titanium implant toxicity82030265355Titanium implant corrosion20485988122120Titanium allergy255212230Yellow nail syndrome223031396173Total94178236408730722Open in a separate window

Table 2

DentalOrthopedicMedicalEnvironmentBasicTitanium toxicity82102150252643Titanium alloy toxicity423035537Titanium implant toxicity375622374Titanium implant corrosion14563227220Titanium allergy222620215Yellow nail syndrome––250–6Total328277499269995Open in a separate window

Within the “Toxicity of titanium” section, studies with regard to liver, lung, and kidney cytotoxicity in human cells and the accumulation of titanium particles were summarized. Within the “Toxicity of titanium alloys” section, we summarized the cytotoxicity of titanium alloys and the inflammatory response of surrounding tissues caused by titanium alloys. Within the “Toxicity of titanium implants” section, we reviewed the inflammatory response to titanium corrosion, hypersensitivity to titanium, and the potential risks of nanoparticles used in titanium implants. Finally, we reviewed the toxicity of titanium by surveying yellow nail syndrome as a disease related to titanium and discussed the risks and potential risks of titanium.

Toxicity of titanium

Titanium is used in various applications such as cosmetics, paints, food products, drugs, and medical implant materials including dental implant [22, 23]. Currently, the most commonly used form of titanium is TiO2 powder. As the production of TiO2 powder continues to expand, there has been an increase in concern of its influence on human and environment [24, 25]. Numerous studies reported the presence and toxicity of TiO2 nanoparticle in both animal models and cultured human cell.

The toxicity of TiO2 nanoparticles (TiO2-NP) in rodents has been reported. Many authors studied the serum biochemical parameters, pathology changes, and the biodistribution of TiO2-NP in the liver, kidneys, lung, spleen, and brain tissue by facilitating a variety of methods including blood biomarker assays, histopathological examination, etc. The dependence of experiment results on the intake (inhalation, oral administration, intraperitioneal/intravenous injection), dosages, and different sizes of nanoparticles was also discussed [21, 26–33].

In two studies regarding the pulmonary response of rodents to subchronic inhalation of TiO2-NP, Bermudez et al. reported a dose-dependent expression of lung burdens in mice, rats, and hamsters in exposure to a wide range of TiO2 pigment. Rats also developed a unique progressive fibro-proliferative lesions alveolar epithelial metaplasia in response to high dose of TiO2-NP [21, 31]. Warheit et al. also reported the species-specific keratin cysts in rats under the overload exposure condition [30].

The acute toxicity and biodistribution were discussed in Wang et al., Chen et al., and Fabian et al. studies [26–28]. Wang et al. [26] reported the injury in the liver (hydropic degeneration around the central vein in the liver and spotty necrosis of the hepatocyte) and kidneys (the BUN level was increased with pathologic renal changes) after oral administration with large dose (5 g/kg body) of different sizes of TiO2 particles (25, 80, and 155 nm). The biodistribution examinations also showed predominant accumulation in the liver, kidney, spleen, and lungs of TiO2, which indicated the ability of TiO2 be transported to other organs after oral intake. Following this report, Chen et al. [27] also reported the pathological changes of the spleen, heart, liver, lung, and kidneys caused by acute toxicity in rats injected with TiO2-NP. The influence of TiO2 on the central nervous system (CNS) is gaining attention recently. Valentini et al. investigated the toxicity of TiO2-NP to the cortical neuron cultures and in the brain of rats, reported the clear impact of TiO2-NP on the neuronal cells and rat brain, and indicated the new evidences of TiO2-NP toxicity in CNS [32].

While there have been reports of titanium toxicity in animal models, Fabian et al. and Warheit et al. [28, 34] reported that the risk of titanium toxicity was not significantly high. In a low-dose TiO2 experiment, Fabian et al. [28] reported no obvious toxic health effects and no detectable inflammatory response or organ toxicity in the rats intravenously injected with suspension of TiO2 in serum (5 mg/kg body weight), despite of the expected biodistribution. In addition, Warheit et al. introduced ten different toxicity studies to form a base set of hazard test for TiO2 ultrafine particle and found that most of the studies indicated low hazard potential in mammals or aquatic species [34].

The effects of TiO2 nanoparticle toxicity in the cultured human cell were also studied [35–39]. There have been a variety of human cell lines used in TiO2 toxicity assessment experiments, including mesothelial cell, epithelial cell, trophoblast cell, and lymphoblastoid cell. In vitro studies reported by Wang et al. showed UF-TiO2 genotoxicity and cytotoxicity in human lymphoblastic cells, with the induction of apoptosis following exposure to UF-TiO2 [35]. Kuku and Culha used surface-enhanced Raman spectroscopy (SERS) for the multidimensional cellular dynamic information to exam the toxic response to TiO2-NP of three cell lines of vein (HUVEC), lung carcinoma (A549), and fibroblast in skin (L929). The results pointed out that L929 is the most resistant cell line, while the HUVEC and A549 cell lines showed the collagen and lipid deformative phenomenon, respectively [36]. Even though the pathological changes such as apoptosis and fibro-proliferative expression of the epithelial cells have been studied in several animal models, its precise mechanism is still not determined. Recently, Kim et al. reported an in vitro experiment regarding the expression of mucin genes in human airway epithelial cells. The authors confirmed that TiO2-NP initiated the TLR4-dependent pathway, leading to the MUC5B overproduction, which relates to the inflammatory response in human airway [37]. In Suarez-Lopez del Amo et al. experiment, the TiO2 particles derived following implantation were collected and co-cultured with the oral epithelial cells (NOK-SI). Two markers DDR and BRCA1 were used to detect DNA damage repair. The authors suggested that compared to DDR, BRCA1 is an optimal marker for detecting DNA damage induced by Ti particles [38].

Ti implants are always inserted into diverse complex body environments which contain various inorganic and organic molecules, as well as living cells. Therefore, besides the behavior of Ti particles in animal body and cell culture, the influence of serum proteins or other biomolecules on titanium implant has been studied under different experimental conditions. Jackson et al. studied the absorption behaviors of bovine fibrinogen and bovine serum albumin (BSA) at the commercially pure titanium surface [40]. The releasing of titanium particles into surrounding tissue by protein adsorption and subsequent desorption of formed metal-protein complexes can cause varieties of tissue reactions. It has been also demonstrated that some conditions such as inflammation or formation of microbial biofilm can lead to a locally acidified environment, and this environment can be potentially harmful to titanium implant. Yu et al. gave attention to lipopolysaccharide (LPS) due to its crucial role as a mediator in peri-implant inflammation. The study demonstrated that LPS significantly inhibited Ti release under the low acidic conditions (pH = 2) but promoted Ti release at the mildly acidic and neutral pH levels, which supposed to be encountered in the peri-implant environment [41].

To approach the mechanism of body reaction to TiO2-NP, many studies reported inflammatory effects due to TiO2-NP exposure, including the presence of pro-inflammatory mediators, macrophage inflammatory proteins, and other inflammatory molecules [42]. The interaction between TiO2-NP and inflammatory cytokines, including CXCL8, a clinically relevant pro-inflammatory chemokine, was also investigated by Batt et al. [43]. The authors found that the TiO2-NP could preferentially adsorb CXCL8 (and IFN-γ), which leads to the disruption of neutrophil chemotaxis and modifies local inflammatory mediator concentration and might result in hampered inflammatory response.

The potential risks of TiO2 accumulation in the body have been followed by reports of metal debris from titanium prosthesis wear. According to Engh et al.’s report [44], the accumulation of metal debris such as titanium, aluminum, and vanadium was found in the bone marrow of two patients who had implanted joints in the iliac. One of the two patients was diagnosed with leukocytopenia, anemia, and general weakness. Although it is questionable that whether these conditions were due to an accumulation of titanium toxicity or not, attention needs to be paid to the fact that metal debris from worn out implants can accumulate in the liver, spleen, and bone marrow, causing adverse effects on the body and systemic disease.

Toxicity of titanium alloy

Titanium alloys have many applications in medical implantation, including orthopedic prostheses and dental implant. Various studies have been conducted regarding the effects of metal particles which worn out from orthopedic prostheses [45]. In 1981, Rae [46] performed experiments in which human synovial fibroblasts were exposed to various preparations of metals and alloy, including pure titanium and wear debris from titanium alloy (Ti-6Al-4V). In the experiment conditions, fibroblasts incubated with pure titanium and titanium alloy showed no significant increases in lactate dehydrogenase and no morphological change. Besides, due to the high solubility of vanadium in the cultured cells, the author estimated that the vanadium from titanium alloy might be potentially harmful to the cell.

In 1993, Haynes et al. [47] performed experiments using titanium-aluminum-vanadium (Ti-Al-V) and cobalt-chromium (Co-Cr) particles of similar size range and concentration similar to those found in failed hip prostheses. In the abdominal macrophage experiments of rats, Co-Cr yielded a high toxic response while Ti-Al-V increased the release of inflammation-inducing mediators such as prostaglandin E2, interleukin-1, interleukin-6, and tumor necrosis factor. These results implied that debris particles of worn Ti-Al-V could induce the release of inflammatory mediators affecting the tissues surrounding the prosthesis and cause osteolysis. Rogers et al. [48] tested the toxicity of vanadium and niobium in titanium alloys; human monocytes released more inflammatory mediators due to Ti-Al-V compared to titanium-aluminum-niobium (Ti-Al-Nb). The authors thus suggested that metal debris particles might lead to bone loss around the prosthesis.

Studies regarding titanium alloy toxicity were continuously reported in 2000s. Hallab et al. [49] performed experiments using human lymphocytes. Co-Cr-Mo and Ti-6Al-4V were incubated with human serum. This experiment showed that a complex between the protein and metal particles caused a lymphocyte reaction; protein binding with a higher molecular weight caused a larger inflammatory reaction. Dalal et al. [50] experimented with the influence of metal particles in human peri-implant cells, osteoblasts, fibroblasts, and macrophages. Co-Cr-Mo, titanium alloy, zirconium oxide, and zirconium alloy were used. Co-Cr-Mo yielded a toxic reaction that interfered with the viability and proliferation of osteoblasts, fibroblasts, and macrophages. All particles induced inflammatory mediator release to macrophages; Co-Cr-Mo, a titanium alloy, released more inflammatory mediators. These results showed that particles around the metal prosthesis could cause irritation and lead to the failure of orthopedic prostheses.

The behavior of titanium alloy in body environment is affected by complex factors. Yu et al. investigated the synergistic effect of albumin and H2O2 on corrosion of Ti6Al4V in physiological saline. In the presence of both H2O2 and albumin, there was a very much higher rate of metal release from Ti6Al4V compared to the presence of albumin and H2O2 alone [51]. Furthermore, in a recent study, Zhang et al. continuously worked on the synergistic effect of albumin and H2O2 on corrosion of Ti6Al4V in physiological saline with electrochemical method and showed the time-dependent dissolution of Ti6Al4V [52]. The experiment showed that albumin suppressed the dissolution in the presence of H2O2 at short periods (< 24 h), but over longer time periods, the dissolution rate increased, which might be attributed to the reduction of oxide film due to albumin-catalyzed dissolution of H2O2 corrosion products. The authors emphasized the importance of a realistic solution and a longer time period experiment design in testing corrosion resistance of metallic biomaterials.

In dental titanium implants, it was suggested that implantation failures may be caused by inflammatory reactions in surrounding tissues due to titanium alloy corrosion or the allergic reaction to titanium and titanium alloys [2, 3]. This topic will be discussed below.

Toxicity of titanium implants

According to the American Society for Testing and Materials (ASTM), there are four grades of commercially pure titanium (CpTi) used in implant biomaterial. The grades I–IV CpTi have different purity grades, with different amounts of interstitial elements (carbon, oxygen, nitrogen, hydrogen, and iron). The grade V refers to the titanium alloys Ti-6Al-4V, which is the most commonly used alloy. Besides, currently, a variety of nanometerials are used for the surface treatment of titanium-based dental implants. Among those coating material, two titanium-contained coating materials are Ti and TiN (Titanium Nitride) which have been studied and advocated to improve the chemical and wear resistance of titanium implant [53]. Even though titanium and its alloys are considered as the most biocompatible implant material because of their nobly biochemical characteristic, wear and corrosion still occur especially in an extreme environment like oral. The released particle can come from the titanium coating layer or from the titanium implant itself. Both phenomena have been studied and reported in many articles and will be reported separately.

Maritini et al. compared implantation of titanium powder plasma-spray-coated titanium screws (TPS-Ti) and fluorohydroxyapatite-coated titanium screws (FHA-Ti). Authors reported the evidence of titanium dispersion inside the medullary spaces when TPS-Ti was implanted, which was the result of friction occurring at the implant surface-host bone interface, leading to loss of integration in the coating layer and release of the detachment of metal particles to surrounding tissue [54].

It is well established that titanium dioxide forms and covers the surface of implant, which makes it highly resistant to corrosion. However, in recent studies, particles of implants were found in peri-implant tissues, which may strongly suggest that a corrosive process has occurred on the titanium implant. The effect of different environmental factors on dental implants was also studied. There are reports that corrosion is significant in conditions which have low pH or high concentration of fluoride [55–58]. In an in vitro study by Strietzel et al. [55], influence of the presence of fluorine on titanium corrosion was detected. Corrosion is further enhanced at lower pH and less influenced by organic acids and their pH values. Schiff et al. [57] tested the effects of fluorine and pH on titanium and titanium alloys and found that fluorine ions could destroy and corrode titanium and titanium passivation layer. The titanium alloys that were used were Ni-Ti, Ni-Ti-Co, and TiAl6V4. Furthermore, in a recent study, Penarrieto-Juanito et al. evaluated ion releases from dental implant systems in fluoride and hydrogen peroxide and examined the surface changes in this process. SEM images indicated the excessive oxidation in implant-abutment joint surfaces along with releasing of Ti, Al, and V ions after being immersed in 1.23% sodium fluoride gel, while no significant corrosion was observed in hydrogen peroxide environment [58].

Recently, there are more studies working on the linking of titanium implants and implant complication or failure. Wachi et al. reported that Ti ions may be involved in the deteriorating effects of peri-implant mucositis, which can develop into peri-implantitis accompanied by alveolar bone resorption [59]. Olmedo et al. reported two cases of reactive lesions of peri-implant mucosa associated with titanium dental implants, one case was diagnosed as pyogenic granuloma and the other case as peripheral giant cell granuloma. The presence of metal-like particles in the tissues suggests that the etiology of the lesions might be related to the corrosion process of the metal structure. In a previous study, the authors found macrophages loaded with titanium particles as indicators of the corrosion process in the soft peri-implant tissue of failed human dental implants [60].

Assuming the implant particle can be an initiator of the peri-implantitis, many studies have been performed to approach the oral mucosa tissue’s response to titanium implant as well as implant cover screws. To determine the correlation between titanium particles and peri-implantitis, Olmedo et al. performed the exfoliative cytological test and observed particles inside and outside the epithelial cells and macrophages. Also, the experiment pointed that the concentration of implant particles in the peri-implantitis group was significantly higher than in the control group [61]. The recent study of Penmetsa et al., in which the exfoliative cytology was also used to detect the titanium particle in a group which has mild gingivitis and another group which has moderate-to-severe condition, also has the similar result. Sixty percent of the specimens in the moderate-to-severe group had titanium particles in peri-implant cytology [62].

In Wilson et al. study, 34 among a total of 36 human peri-implantitis biopsies were analyzed [63]. The SEM images revealed the predominant titanium particle surrounded by inflammatory cells. The study mentions three possibilities that can cause the presence of titanium particle in surrounding tissue. They are the releasing due to the friction between implant and bone surface during installation, the wear during debridement at maintenance visits, and the corrosion [63]. Fretwurst et al. reported the metal particle in peri-implant soft tissue along with M1 macrophages and the increasing in titanium concentration with lymphocytes detection [64]. In association with the metal particle releasing, the damage of implant surface during the installation procedure was also determined [65].

On the other hand, a study of Addison et al. using synchrotron X-ray microfocus spectroscopy in order to detect trace distribution of Ti in tissue demonstrated a scattered and heterogeneous distribution of Ti in inflamed tissues taken from around skin-penetrating Ti implants. The location and distribution characteristics of Ti particles suggested that debris from implant placement are unlikely to be the major contributors. The authors proposed that Ti in the tissue results can be derived from micro-motion and localized corrosion in surface crevices [66].

One of the causes of implant failure can be attributed to allergic reactions to titanium. There have been reports of hypersensitive reactions such as erythema, urticaria, eczema, swelling, pain, necrosis, and bone loss due to titanium dental implants [15, 67, 68]. Despite of the limitation of the case report, these cannot be neglected. In several case reports in which titanium allergy was initially suspected, upon further investigations, the allergic agents were other metals [69]. The reliability of the patch test for current titanium is not guaranteed for clinical use. Therefore, it seems that future studies and countermeasures are necessary [70].

The case for allergies after installation of titanium dental implants was recorded by Hosoki et al. [14] at a 69-year-old male. The patient had the successful dental implantation in 2008. An allergic eczema reaction occurred in 2010 after inserting of a titanium screw due to a leg fracture. The titanium screw was removed a year later; however, the eczema was only reduced by 50%. All metal prostheses except the implant screw and abutment were removed, and the eczema reaction was reduced to 30%; the symptoms still remained. The removal of the titanium implant screw and abutment in 2014 led to a full recovery. In Korea, allergy condition has also been reported after the installation of titanium implants [15]. In 2012, a 70-year-old woman exhibited a stomatitis that appeared to be an allergic reaction. There was no evidence of metal hypersensitivity in this patient. There were no problems with the implant placement; however, after the abutment was raised and the prosthesis was made, the patient complained of pain. Removal of the prosthesis confirmed erythema on the gingiva around the abdominal cavity. Allergic symptoms were suspected to be due to TiN-coated abutments, and symptoms improved after the use of titanium abutments. A patch test showed a positive result for TiN.

Allergic reactions to titanium materials have also been reported with orthopedic prostheses. Thomas et al. [71] reported eczema symptoms and improper bone formation in the case of a 35-year-old male patient with a titanium implant in the fracture of his hand. In this case, the patch test showed a negative reaction to titanium, nickel, chromium, cobalt, etc. However, the lymphocyte transformation test showed an increased pattern for titanium. Additionally, in 1991, Lalor et al. also reported hypersensitivity reactions to titanium and reported the proliferation of inflammatory cells in patients with failed orthopedic prostheses [72].

Although the biocompatibility of titanium has been evaluated to be good because it causes less hypersensitive reaction than other metals, it does not mean that allergy symptoms related to titanium do not exist. Previous reports have shown that hypersensitive reactions to titanium and titanium alloys can lead to failures in clinical treatment. Therefore, allergy symptoms of titanium or titanium alloy components should also be accounted for a related factor to dental implants failures.

Titanium-related diseases

It has been reported that systemic disease can occur due to titanium. According to a study by Berglund and Carlmark [17] in 2011, titanium can be attributed to the cause of “yellow nail syndrome.” In 30 patients with yellow nail syndrome, energy-dispersive X-ray fluorescence (EDXRF) was used to measure the titanium content in the nails of patients; the titanium content was found to be high, and titanium was identified as the cause of yellow nail syndrome. Yellow nail syndrome is characterized by a change in the nails, bronchial obstruction, and lymphedema. Berglund and Carlmark also reported that postnasal drip and cough-associated sinusitis are the most common symptoms found in yellow nail syndrome patients.

Yellow nail syndrome was first designated as a medical term by Samman and White [73] during their report of a patient with nails growing slowly, thicker, and yellowish in color in conjunction with lymphedema syndrome. These cases also reported recurrent pleural effusion, intermittent coughing with bronchial asthma accompanied by sputum, bronchiectasis [74–76], and inflammation in the maxillary sinus and sinus [77–81]. In 1994, Varney et al. [79] reported 17 patients with yellow nail syndrome. Among that, 14 patients had rhinosinusitis (83%) and had daily mucopurulent rhinorhoea and nasal obstruction. The onset of nasal symptoms could predate nail change or appear at the same time. Additionally, in 2014, Piraccini et al. [81] reported that the mean patient age was 57 years in a report of 21 patients; most patients had a history of pathology in which 16 patients experienced chronic respiratory disease and six patients had lymphadenopathy. A change in nail color appeared to be a symptom that was revealed after progression of the disease and did not necessarily have to occur. Lymphedema was also seen when the disease persisted for a long time. Pleural effusion was the most common lung change, and chronic sinusitis was reported to occur with an early onset. At least 10 of 20 patients were reported to show an improvement in symptoms after 6 months of continuous vitamin E1 administration at 200 IU/day; however, there was a continuous debate regarding the medication details.

Efforts to elucidate the pathogenesis of yellow nail syndrome are currently underway. In 2001, D’Alessandro et al. [76] reported that the protein content of pleural effusions was high in yellow nail syndrome patients and reported the relationship between hypoalbuminemia and a reduction in systemic albumin. As mentioned above, in 2011, Berglund and Carlmark [17] evaluated 30 patients with yellow nail syndrome via EDXRF and found that titanium was detected in yellow nail syndrome. Titanium was thus judged to be a pathogen of yellow nail syndrome. The main source of titanium ions was reported to be due to corrosion caused by galvanic effects between titanium implants and gold and/or amalgam restorations and corrosion due to fluorine oxidation. In 26 patients with titanium implant, including 20 patients with titanium implants in the jaw and mouth, 20 patients with gold restorations in the mouth, 2 patients with amalgam restorations, and 2 patients with gold rings, oral galvanic action was possible. In 4 of these patients, removal of the gold restoration resulted in a recovery of the symptoms originating from galvanic action. Patients with implants with a symptomatic recovery experienced a recurrence of symptoms when later exposed to titanium again. In 3 patients, dental titanium tools were exposed to fluoride gels and fluoride solutions [17]. In some other patients, titanium dioxide contained in drugs was considered to be the source of titanium ions. Four male and 4 female patients suffered from yellow nail syndrome after eating TiO2-containing medication such as diclofenac, celecoxib, and zopiklon, along with gum, candy, and licorice. In this case, symptoms were remedied by not using medication [17]. Other reports showed a case of yellow nail syndrome after drug ingestion of medicine containing TiO2. In these reports, symptoms improved when drug usage was discontinued [17, 82].

There are numerous reports showing the association between titanium and yellow nail syndrome in addition to the above reports. In 2015, Decker et al. [19] reported a case of a 67-year-old female patient who had lost her claws 18 months prior and had changes in bronchitis, sinusitis, and nails within the last 5 years. Inhaled corticosteroids were used for initial continuous cough symptoms but were not effective. These early respiratory symptoms were followed by changes in nails 3 years later. At the same time, Pseudomonas aeruginosa bronchitis and sinusitis were experienced. Lymphedema was not observed, and vitamin E 1600 IU/day treatment was prescribed. EDXRF of the nails revealed high levels of titanium; eight amalgam restorations and fluoride-containing toothpastes were used daily in the oral cavity. She was also reported to have a history of regular titanium dioxide intake through cetirizine (10 mg/day) and gum (4–8 piece/day). Ataya et al. [20] reported a 56-year-old woman with appearance of yellow nail syndrome symptoms immediately after implantation. Chronic sinusitis, cough, a change in nails, and maxillary sinusitis were all recovered after implant removal. However, they reported that there was no change in the nails. This report also showed that yellow nail syndrome was associated with titanium. Dos Santos [83] also reported the association of yellow nail syndrome with titanium in 2016, and De Lima and Dos Santos et al. [84] reported the observation of titanium accumulation in the liver, spleen, lung, lymph nodes, and bone marrow in the autopsy results of five drug-addicted patients; titanium pigmentation was observed under a microscope. This report revealed a systemic accumulation of titanium, but with no change in the nails.

As in the aforementioned reviews, the accumulation of titanium has been observed in patients with “yellow nail syndrome” and the relationship is currently being discussed in greater detail. There have been several reports of the relative association between titanium and yellow nail syndrome at the beginning of Berglund and Carlmark’s report [17]; on the contrary, there was no evidence of “yellow nails” in the anatomical studies of patients who were drug addicted. This is still a controversial topic which is still in debate. Therefore, further studies are needed to determine the relationship between titanium and yellow nail syndrome and the pathogenesis.

What factors should be considered when selecting an electrochemical charge for tensile testing?

5 answers

When selecting an electrochemical charge for tensile testing, several factors should be considered. Firstly, the electrochemical environment plays a crucial role in the tensile process, affecting mechanical cracking of passive layers and corrosion initiation. Additionally, the presence of hydrogen as a surface hydride layer can impact the tensile properties of the material, with continuous surface hydrides potentially altering yield strength and ultimate tensile strength. Furthermore, the design of the testing device is essential, with features like a dynamic hydrogen charging slow tensile test device offering advantages such as accurate experiment parameters and good sealing performance. Overall, the selection of an electrochemical charge for tensile testing should consider the impact on mechanical properties, corrosion processes, and the ability to simulate actual working conditions.

What are the current advancements in 3d printing technology for cartilage implants in veterinary medicine?

4 answers

Recent advancements in 3D printing technology for cartilage implants in veterinary medicine include the use of materials like titanium and titanium alloys for creating individualized implants. Additionally, the integration of 3D-printed frameworks, such as polycaprolactone (PCL), with engineered cartilage gel (ECG) has shown promising results in cartilage regeneration in large animals. Furthermore, in situ bioprinting has emerged as a novel strategy for directly delivering bioinks to the affected anatomical site, potentially overcoming limitations associated with conventional bioprinting techniques for cartilage repair. These advancements in 3D printing technology offer customizable solutions based on individual patient needs, reducing surgical intervention time, promoting better osseointegration, and enhancing the overall efficacy of cartilage regeneration in veterinary medicine.

Effects of chromium on humans lungs?

5 answers

Chromium, specifically hexavalent chromium (Cr(VI)), poses significant health risks to human lungs. Exposure to Cr(VI) can lead to lung carcinogenesisand toxic effects on bronchial epithelial cells, causing alterations in cell viability, cell cycle progression, and gene expression. Furthermore, prolonged exposure to Cr(VI) can initiate lung tumorigenesis by transforming stem-like cells in the lungs, promoting tumor formation through upregulation of ALDH1A1 and EGF biosynthesis. Additionally, chromium oxide nanoparticles induce genotoxicity and apoptosis in human lung epithelial cells, highlighting the need for regulations in nanoparticle usage. These findings underscore the importance of understanding and mitigating the detrimental effects of chromium on human lungs to protect against lung cancer, cell damage, and potential carcinogenesis.

What is the success rate of dental implant placement in patients with cemento osseous dysplasia?

5 answers

Dental implant placement in patients with cemento-osseous dysplasia (COD) has shown varying success rates. Studies have indicated that conventional implants have survival rates exceeding 90% for the first five years among patients with ectodermal dysplasia, a related condition. In the case of COD, a successful implant placement with an 8-year follow-up was reported in a patient with florid COD, demonstrating rigid fixation and successful restoration without complications. However, COD can present challenges due to its radiographic appearance and potential complications such as poor healing and infection. Dentists need to be cautious in diagnosing and treating COD to avoid compromising patient health, as mismanagement can lead to osteomyelitis in symptomatic cases. Therefore, while dental implants remain a viable treatment option, careful assessment and monitoring are crucial in patients with COD.

What is the Pottasium Standard value for plant growth?

5 answers

The optimal potassium standard value for plant growth varies depending on the crop type and environmental conditions. Research findings indicate that applying potassium fertilizer at specific rates significantly enhances yield and yield components of various crops like wheat, rice, and sugar beet in different regions like Egypt, Turkey, Romania, Pakistan, Saudi Arabia, and India. For instance, the maximum yield of wheat was recorded at 60 kg K2O/ha in Pakistan, 200 kg K2O/ha in Saudi Arabia, and 50 kg ha−1 K2SO4 in India. Additionally, studies on pearl millet demonstrated that using potassium at a rate of 60 kg/ha, along with specific plant growth regulators, led to optimal growth parameters and yield. Therefore, it is essential to consider crop-specific requirements and environmental factors when determining the potassium standard value for plant growth.

What is hydroxyapatite?

5 answers

Hydroxyapatite (HA) is a significant biomaterial extensively utilized in various fields such as medical implants, dental care, and drug delivery systems. It closely mimics the mineral composition of bones and teeth, exhibiting bioactive, osteoconductive, and non-toxic properties. HA's structure, with nano-sized particles and positive/negative charges, enables efficient absorption of biomolecules, making it ideal for applications in electrochemical biosensors. In oral care products, HA is used for its preventive effects, often combined with other active ingredients like lactoferrin, xylitol, zinc, allantoin, bisabolol, and hyaluronic acid to enhance antibacterial properties and promote gum health. The synthesis of HA involves advanced techniques like infrared spectroscopy, X-ray diffraction, and scanning electron microscopy, providing insights into its structural arrangements and physico-chemical properties.

How much waste is produced in material processing for cobalt-chromium?

4 answers

In material processing for cobalt-chromium, significant amounts of waste are generated. The United States alone releases over 2,000 metric tons of cobalt annually from mining and mineral processing, with additional losses during chemical and powder processing estimated at 50-80 metric tons per year. In Brazil, stainless steel production results in the generation of more than 7,000 tons of dust containing chromium, nickel, iron, and lead, posing environmental challenges. Furthermore, the global steel production in 2010 led to substantial waste generation, with steelmaking slags being a notable byproduct that requires constant monitoring due to its changing composition and potential environmental hazards. Therefore, the processing of cobalt-chromium materials results in a considerable volume of waste that necessitates proper management and recycling practices to mitigate environmental impacts.

What are the coating methods that use titanium powder to create good quality coating?

4 answers

Various coating methods utilize titanium powder to create high-quality coatings. One method involves a packed-powder diffusion coating (PPDC) technique, which forms a controllable Al3Ti intermetallic-based composite coating on pure Ti and Ti alloys, enhancing their oxidization and wear resistance. Another method focuses on preparing a modified titanium white powder coating by coating titanium white powder particles with a film coating material, such as hydroxide, to enhance glossiness and dispersity in coatings. Additionally, a method for coating powder materials with titanium dioxide involves soaking the powder material in a titanium salt solution under nitrogen protection, followed by drying and calcining to obtain a uniform titanium dioxide coated layer at different temperatures, ensuring high utilization of titanium salt and uniform coating effects. These methods showcase the versatility of titanium powder in creating effective coatings.

What is the EU and US against in the new steel club?

5 answers

The EU and US are not against steel clubs; instead, they are working towards a deal on critical minerals. Decarbonizing global steel production is a priority, requiring a fundamental transformation that can be facilitated by a sectoral climate club involving deep transnational cooperation. Steel production is significant in various European countries, with new Member States like Poland, the Czech Republic, Slovakia, Hungary, and Slovenia collectively producing around 23 million tonnes of liquid steel annually, providing numerous jobs. Additionally, an alloy for golf club heads with specific compositions, including manganese, aluminum, carbon, chromium, iron, silicon, titanium, and molybdenum, has been developed to enhance corrosion resistance and mechanical properties.

List all the titanium alloy with a Young's modulus between 40GPa-60GPa, which alloy is possibl?

5 answers

Titanium alloys with a Young's modulus falling between 40 GPa and 60 GPa include Ti–Nb–Zr–Fe–O alloy with a Young's modulus of about 48–49 GPa. Additionally, Ti-alloys with low Young's modulus are crucial for biomedical applications to prevent stress shielding, and various factors like phase stability, alloying elements, plastic deformation, and texturing influence the Young's modulus. Moreover, Ti–Mo and Ti–Cr alloys are considered for spinal fixation devices due to their ability to adjust Young's modulus, with Ti–12Cr being the most suitable option. The accurate determination of Young's modulus in Ti alloys is essential for design purposes, and a combinatorial method involving diffusion couples, nanoindentation, EPMA, and CALPHAD techniques has been used to establish a Young's modulus database for Ti alloys with various compositions.

What is the articles about Pt micro-heater with IDT MEMs devices?

5 answers

The articles discussed various aspects of Pt micro-heaters in MEMS devices. Singh et al. compared Pt micro-heaters with Ti and TiN, showing Pt's thermal coefficient of resistance (TCR) of 2641 ppm/°C and its comparable power-temperature characteristics. Fritsch et al. highlighted the integration of Pt metallization in MEMS packages for harsh environments, emphasizing its use in gas sensors for agriculture applications. Additionally, a study by Salvatore and Santangelo described a micro-heater element design with a heat-diffusion structure and connection elements, showcasing the role of Pt in dissipating energy and distributing heat within MEMS sensor devices. These papers collectively demonstrate the significance of Pt micro-heaters in MEMS devices, showcasing their thermal properties, integration in harsh environments, and design features for efficient heat distribution.

General review of titanium toxicity

What are the advantages and disadvantages of titanium alloys?