Limit Switch Functional Check - JLG 600s Operation And Safety Manual [Page 28]

10 Oct.,2023

 

SECTION 2 - USER RESPONSIBILITIES, MACHINE PREPARATION, AND INSPECTION

2.3

limit switch FUNCTIONAL CHECK

TO AVOID COLLISION AND INJURY IF PLATFORM DOES NOT STOP

WHEN A CONTROL SWITCH OR LEVER IS RELEASED, REMOVE FOOT

FROM FOOTSWITCH OR USE EMERGENCY STOP TO STOP THE

MACHINE.

NOTE: Perform checks from ground controls first, then from plat-

form controls.

1. Operate machine from ground control.

NOTE: For adjustments see Service Manual - Limit Switch Adjust-

ments.

2. Check elevation limit switch as follows:

a. Lift boom up to 2 degrees to 7 degrees above hori-

zontal. The switch should activate at this point.

b. Lift boom down to 2.5 degrees to 7.5 degrees

below horizontal. The switch should reset at this

point.

2-6

3. Raise main boom, extend and retract telescope. Check

for delayed movement of fly section, indicating loose

cables.

4. Swing turntable to LEFT and RIGHT a minimum of 45

degrees. Check for smooth motion.

NOTE: Step 5 is only applicable for machines with an external tilt

sensor.

5. With the aid of an assistant to monitor the CHASSIS

OUT OF LEVEL indicator light on the platform control

console, manually activate the indicator light by com-

pressing any one of the three tilt indicator mounting

springs. If the light does not illuminate, shut down

machine and contact a qualified service technician

before continuing operation.

NOTE: Step 6 is applicable for machines with an internal tilt sen-

sor.

6. Check the chassis out of level indicator located on the

platform control console by driving, with the machine in

level position, up a suitable ramp of at least 5° slope.

Check the out of level indicator, with the machine on the

ramp. If the light does not illuminate, return the machine

to a level surface, shut down the machine, and contact a

qualified technician before resuming operation.

– JLG Lift –

3121205